ECM - Static is a highly sophisticated system, which allows static bearing capacity to be measured by using world-wide known Static Plate Load Bearing Test. Significant simplifications of this field method on wide range of road, airfield, industry and dam construction. Allows measurement according up to 3 hard-coded algorhitm (corresponding to valid standards as per user's specification), or according up to 5 free user-definable algorhitm. Possibility of further expanding of the basic system in several steps to the top comfortable system with wide range of user capabilities.
ECM - Static on the construction site (click for a more detailed view)
Static deflection modulus E0 and static modulus of elasticity E determination
DIN 18 134 standard available
Determination of values E1 and E2 and E2/E1 ratio from two subsequent cycles
Possibility of so called reaction modulus K measurement (for some given standards)
Automatic control of the test process by audio signal and text messages on the display
Possibility of additional software pack to control the tests from notebook via USB connection
Full evaluation of the test process and results including the graphic representation
Direct measurement of the load force by tensometric load cell with 0.2% precision
One-point deflection reading by linear position transducer with 1mikron resolution
Basic system allows to store up to 5 tests including graphic representation
Additional memories for storing up to 100 test courses
Possibility of text and graphic printing of test courses from memory
ECM - Static - graph (click for a more detailed view)
Miniature accu-powered graphic printer as a standard accessories
Possibility of data transmission from memory into PC (Notebook)
Standard serial RS232 line connection as a basic system accessories
Full version SW for data acquisition on a PC is also a part of basic system
The real time and the calendar with a standby support power supply as standard accessories
3 possibilities of power supply, 220V AC, 12V DC, including battery charging
Accumulator-battery power supply operating time up to 20 hours
A well arranged membrane alphanumerical keyboard
A well arranged alphanumerical LCD display 2x16 characters
A practical design, alu case for electronic unit, wood case for mechanical parts